Description
Zurn Wilkins 4-375OSY 4" Reduced Pressure Principle Assembly (RP) Backflow Preventer – OS&Y Gate Valves, Lead-Free, Flange x Flange
Product Overview
The Zurn Wilkins 4-375OSY Reduced Pressure Principle Assembly (RPZ) Backflow Preventer provides high hazard protection for potable water systems. With a flanged ductile iron body, OS&Y gate valves, and lead-free construction, it’s engineered to stop both backsiphonage and backpressure from introducing contaminants into drinking water.
Built with a short lay length for tight installations, a low headloss compound check for improved performance, and a single access cover for easier servicing, the 4-375OSY is a proven choice for commercial and industrial backflow prevention.
Features & Benefits
-
4" RPZ Backflow Preventer with OS&Y gate valves for maximum reliability
-
Short lay length simplifies installation in confined spaces
-
Low headloss design improves flow performance in demanding systems
-
Epoxy-coated ductile iron body resists corrosion and extends service life
-
Single access cover allows quick maintenance without full disassembly
-
Flexible connection options with flange x flange ends
-
Lead-free compliant to meet potable water standards
Specifications
-
Size: 4"
-
End Connections: Flanged, ANSI B16.1 Class 125
-
Maximum Working Pressure: 175 PSI
-
Maximum Temperature: 140°F
-
Hydrostatic Test Pressure: 350 PSI
-
Body Material: Ductile Iron, ASTM A 536 with FDA-approved epoxy finish
-
Internals: Stainless steel, NORYL™, EPDM seals, Buna-N O-rings
-
Sensing Line: Stainless steel braided hose
-
Shutoff Valves: OS&Y gate valves (lead-free)
-
Certifications:
-
ASSE® 1013
-
AWWA C511 & C550
-
IAPMO® Listed
-
CSA® Certified
-
UL® Classified / C-UL® Classified
-
FM® Approved
-
USC FCCCHR Approved
-
Meets NSF/ANSI/CAN 61 (≤0.25% weighted average lead content)
-
Installation Tips
-
Install in accordance with local codes and plumbing standards.
-
Mount assembly 12"–30" above floor drains with adequate clearance for testing and service.
-
Ensure relief valve discharge is piped to a safe drainage point.
-
Avoid submersion of any part of the assembly.
-
Test the backflow preventer upon installation and perform routine annual testing.
FAQs
Q: What type of protection does the 4-375OSY provide?
A: It protects potable water systems from high hazard backflow conditions, including both backsiphonage and backpressure.
Q: Can this unit be installed in tight spaces?
A: Yes, its short lay length design makes it ideal for confined installation areas.
Q: Are the OS&Y gate valves included?
A: Yes, this model comes with flanged OS&Y shutoff valves.
Q: Is it compliant with lead-free potable water standards?
A: Yes, it meets NSF/ANSI/CAN 61 requirements with ≤0.25% weighted average lead content.
Q: How often should it be tested?
A: Backflow preventers should be tested at installation and at least annually to maintain compliance.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.